Check out our FAQ section to find out more about energy solutions and generators. If you cannot find answers to your questions here, do not hesitate to contact us. We will be happy to help you.
The category (Standby, Prime, Continuous) is indicated on the label of the generator set. Using above these operating conditions will cause the following problems; Overheating of the engine, Increased wear on the engine, Overheating of the alternator windings, Thinning of the lubricating oil and decrease in oil pressure, Shortening of engine life.
All generator sets produce noise from exhaust, engine casing, fans. It is necessary to take measures according to the installation location. Lomar generator sound insulation cabinets provide the optimum solution by providing maximum sound control.
You should follow the schedules in the Maintenance and Operation Manuals supplied with your generator set. However, a number of factors may cause you to increase the frequency of maintenance and inspection. Frequency and duration of operation, load condition, oil-fuel quality, ambient temperature, dirty-dusty environment, etc. The user is responsible for maintenance, inspection and timely replacement of worn materials (engine oil, filters, V-belts, antifreeze, injectors, etc.). We recommend general checks, adjustments and tests every 2-3 months. General maintenance and engine oil-filter replacement should be done once a year even if the operating hours are not completed. You should also test your generator set once a week for 10-15 minutes under load. Please contact Lomar Generator for safe, accurate and economical maintenance and controls of your generator set.
Determining the power of a generator set is a specialized task and depends on many factors. From the category of operation to the characteristics of your loads, from ambient conditions to product options, there are many things to consider. You can get help in this regard by contacting Lomar Generator.
It is as unfavorable to use the generator set at low loads as it is to use it above the capacity specified on the label values. Such use will shorten the engine life and cause serious damage. Particular attention should be paid to this situation especially in the use of large power generator sets. The minimum permitted load for standby generator sets is 30% of the total power.
You can obtain all consumables and spare parts for your Lomar generator from our regional dealers. You can also get information and offers from Lomar Generator for your spare parts requests for all brands of engines, alternators and generator sets.
The number of revolutions of the generator set in 1 minute. Generally, engines and alternators are manufactured at 1500 rpm or 3000 rpm for 50Hz and 1800 rpm or 3600 rpm for 60Hz.